Advanced Ultrasound in Diagnosis and Therapy ›› 2019, Vol. 3 ›› Issue (2): 50-52.doi: 10.37015/AUDT.2019.190810

• Case Report • Previous Articles    

Inflammation Spreading from Subacute Thyroiditis Following Fine-needle Aspiration: A Case Report

Bowen Zheng, MDa, Tao Wu, MDa, Ying Ruan, MDb, Jun Chen, MDa, Jie Ren, MDa,*()   

  1. a Department of Medical Ultrasonics, Guangdong Province Key Laboratory of Hepatology Research, the Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, 510630, China
    b Department of Thyroid and Breast Surgery, Guangdong Province Key Laboratory of Hepatology Research, the Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, 510630, China
  • Received:2019-03-27 Online:2019-06-30 Published:2019-06-28
  • Contact: Jie Ren, MD, E-mail:renjieguangzhou@126.com

Abstract:

Ultrasound guided fine-needle aspiration (FNA) is well-accepted in the evaluation of thyroid nodules. Though local pain and minor hematomas are the most common complications, other adverse events following FNA are rare. In this case report, we described a complication showing inflammation spreading in a healthy woman after FNA. We presented the case to make physicians aware of the potential complication.

Key words: Thyroid; Biopsy; Fine-Needle; Thyroiditis; Subacute; Complication; Inflammation