ADVANCED ULTRASOUND IN DIAGNOSIS AND THERAPY >
Localization of Nonpalpable Breast Lumps by Ultrasound Local Coordinates and Skin Inking: A Randomized Controlled Trial
Received date: 2022-09-01
Revised date: 2023-02-03
Accepted date: 2023-02-21
Online published: 2023-10-09
Background and Purpose: Surgery of ultrasound-detected non-palpable breast lesions should be guided by ultrasound. Commonly radiologists localize the lesion under ultrasound preoperatively, which necessitates the availability of a localization device and may involve a substantial cost. We performed a study to prospectively assess the feasibility of ultrasound-guided localization without any special device.
Methods: Women with non-palpable benign breast masses were assigned to the “guide wire insertion” (GWI) or the “local coordinates and skin inking” (LOCSI) groups. In both groups, the tumor was marked as a shadow on the skin by the radiologist under ultrasound. In the GWI group, a guidewire was inserted, and in the LOCSI group, the local coordinates of the lesion relative to the skin and the nipple as well as its clockwise placement were reported.
Results: Overall, 29 cases were included in the study, 11 in the GWI and 18 in the LOCSI groups. In all cases, the specimen was correctly excised. The weights of the resected specimens were significantly higher with GWI; LOCSI prevented excessive tissue extraction. Clinicians reported LOCSI as “very easy” more frequently, and surgery took less time.
Conclusions: Overall, our study showed that LOCSI was feasible and can be a suitable method in areas with limited resources. We propose similar studies with a larger sample size, inclusion of malignant cases for margin assessment, and estimation of the cost-effectiveness of the technique.
Leila Bayani, MD , Donya Goodarzi, BS , Reza Mardani, MD , Bita Eslami, PhD , Sadaf Alipour, MD . Localization of Nonpalpable Breast Lumps by Ultrasound Local Coordinates and Skin Inking: A Randomized Controlled Trial[J]. ADVANCED ULTRASOUND IN DIAGNOSIS AND THERAPY, 2023 , 7(3) : 267 -271 . DOI: 10.37015/AUDT.2023.220033
[1] | Fortunato L, Penteriani R, Farina M, Vitelli CE, Piro FR. Intraoperative ultrasound is an effective and preferable technique to localize non-palpable breast tumors. Eur J Surg Oncol 2008; 34:1289-1292. |
[2] | Mayo III RC, Kalambo MJ, Parikh JR. Preoperative localization of breast lesions: current techniques. Clin Imag 2019; 56:1-8. |
[3] | Cheang E, Ha R, Thornton CM, Mango VL. Innovations in image-guided preoperative breast lesion localization. Brit J Rad 2018; 91:20170740. |
[4] | Alamdaran SA, Farokh D, Haddad AS, Daghighi N, Modoodi E, Sadeghi R, et al. Assessment of ultrasound/radio-guided occult lesion localization in non-palpable breast lesions. Asia Ocean J Nucl Med Biol 2018; 6:10. |
[5] | Kasem I, Mokbel K. Savi Scout? radar localisation of non-palpable breast lesions: Systematic review and pooled analysis of 842 cases. Anticancer Res 2020; 40:3633-3643. |
[6] | Nasrinossadat A, Ladan F, Fereshte E, Asieh O, Reza C, Akramossadat S, et al. Marking non-palpable breast masses with injected methylene blue dye, an easy, safe and low cost method for developing countries and resource-limited areas. Asian Pac J Cancer Prev 2011; 12:1189-1192. |
[7] | Tang J, Wang X, Wu YP, Wang X, Lian ZQ, Fu JH, et al. Significance of methylene blue dye for localization biopsy of nonpalpable breast lesions. Chin J of Cancer 2009; 28:79-81. |
[8] | Arian A, Dinas K, Pratilas GC, Alipour S. The Breast Imaging-Reporting and Data System (BI-RADS) made easy. Iranian Journal of Radiology 2022; 19:e121155. |
[9] | Alipour S, Moini A, Orouji M, Saberi A, Motamedi M, Eskandari A. COVID-19 outbreak and consequent delays in schedules of the breast clinic: effects on patients’ breast and emotional symptoms. European Journal of Breast Health 2020; 16:250-254. |
[10] | Zhang Y, Seely J, Cordeiro E, Hefler J, Thavorn K, Mahajan M, et al. Radioactive seed localization versus wire-guided localization for nonpalpable breast cancer: a cost and operating room efficiency analysis. Annals of surgical oncology 2017; 24:3567-3573. |
[11] | Helvie MA, Ikeda DM, Adler DD. Localization and needle aspiration of breast lesions: complications in 370 cases. American journal of roentgenology 1991; 157:711-714. |
[12] | Bronstein AD, Kilcoyne RF, Moe RE. Complications of needle localization of foreign bodies and nonpalpable breast lesions. Archives of Surgery 1988; 123:775-779. |
[13] | Alikhassi A, Saeed F, Abbasi M, Omranipour R, Mahmoodzadeh H, Najafi M, et al. Applicability of radioguided occult lesion localization for nonpalpable benign breast lesions, comparison with wire localization, a clinical trial. Asian Pacific Journal of Cancer Prevention 2016; 17:3185-3190. |
[14] | Medina-Franco H, Abarca-Pérez L, García-Alvarez MN, Ulloa-Gómez JL, Romero-Trejo C, Sepúlveda-Méndez J.Radioguided occult lesion localization (ROLL) versus wire-guided lumpectomy for non-palpable breast lesions: a randomized prospective evaluation. Journal of surgical oncology 2008; 97:108-111. |
[15] | Aydogan F, Ozben V, Celik V, Uras C, Tahan G, Gazioglu E, et al. Radioguided occult lesion localization (ROLL) for non-palpable breast cancer: a comparison between day-before and same-day protocols. The Breast 2010; 19:226-230. |
[16] | Jakub J, Gray R. Starting a radioactive seed localization program. Annals of surgical oncology 2015; 22:3197-3202. |
[17] | Dryden MJ, Dogan BE, Fox P, Wang C, Black DM, Hunt K, et al. Imaging factors that influence surgical margins after preoperative 125I radioactive seed localization of breast lesions: comparison with wire localization. American journal of roentgenology 2016; 206:1112. |
[18] | Gera R, Tayeh S, Al-Reefy S, Mokbel K. Evolving role of magseed in wireless localization of breast lesions: systematic review and pooled analysis of 1,559 procedures. Anticancer Research 2020; 40:1809-1815. |
[19] | Cox CE, Garcia-Henriquez N, Glancy MJ, Whitworth P, Cox JM, Themar-Geck M, et al. Pilot study of a new nonradioactive surgical guidance technology for locating nonpalpable breast lesions. Annals of surgical oncology 2016; 23:1824-1830. |
[20] | Carlino G, Rinaldi P, Giuliani M, Rella R, Bufi E, Padovano F, et al. Ultrasound-guided preoperative localization of breast lesions: a good choice. J Ultrasound 2019; 22:85-94. |
/
〈 | 〉 |